Accuracy ±0.2℃, ±2%RH
Range -40℃ ~ 80℃, 0...100%RH
DescriptionFAQ?

The wireless environmental validation system is widely used in the pharmaceutical, medical, and life sciences fields. Compared with traditional temperature and humidity meters, it has higher accuracy and better stability, making it suitable for temperature and humidity distribution verification in drug warehouses, laboratory equipment, and special storage areas for biological and medical purposes.


FEATURES

  • 10 year Battery Life on a Single Charge:   The H6 temperature and humidity data logger uses a single interface design, with the reader integrating data transmission and charging functions. When reading data, it automatically replenishes power, keeping the data logger always fully charged, eliminating battery life concerns, and making on-site operations more efficient and worry-free.

  • 5 km Ultra-Strong Penetration Wireless Real-Time Signal: The H8 wireless real-time data recorderuses dual-frequency wireless technology. The dual-frequency ultra-strong signal can achieve high-speed transmission over a super long distance of 5km, fully wireless remote operation, significantly improving work quality and efficiency, and is especially suitable for pharmaceutical warehouses with large spaces and complex environments for validation.

  • Compact and portable: Advanced electronic technology and structural design allow the entire INON series of temperature and humidity recorders to have a compact and portable size and appearance, capable of flexibly adapting to multi-scenario installation and use, enabling efficient and rapid spatial deployment and vertical hanging.


APPLICATION

  • Room Temperature Storage, Cool Storage, Refrigerated Storage, Frozen Storage

  • Laboratory Equipment

  • Ultra-Low Temperature Freezer  


SYSTEM STRUCTURE

The environment validation system   consists of three parts: computer software, read station, and data loggers.   In addition, according to different monitoring targets, the system will also be equipped with relevant external sensors.


Monitoring Solution.pngWireless Monitoring Solution.png






H6 Temperature humidity data logger

温湿度数据记录仪 H6.png

Features

  • 10 years battery life on a single charge: Using a single interface design, the reader integrates data transmission and charging functions, automatically syncing and replenishing power while reading data, keeping the data logger always fully charged, eliminating battery anxiety, and making on-site operations more efficient and worry-free.

  • Simple and fast operation: One-button power on, start collecting immediately.   No complicated configuration is needed, ready to use right away, and external sensors can also be plugged in directly, making it simple and quick, allowing data logging to be easier and more efficient.

  • Compact and portable: Advanced electronic technology and structural design make the form factor compact and small. The logger can flexibly adapt to multi-scenario installation and use, enabling efficient and convenient spatial placement and vertical hanging.

SPECIFICATION

Model #

H6-T1H1

Sensor Channel

1 x Inner PT100, 1x Inner RH%, 1 x External sensor

Measurement range

-40℃ to 80℃, 0%...100%RH

Accuracy

±0.2℃, ±2%RH (at 25℃, 20...90%RH)

Storage capacity

16,000 data / channel

Battery

Rechargeable Lithium Battery, 1500mAh

Working Environment

-40℃ to 80℃, 0...100%RH (no condensation)

Dimension (L x W x H)

83 x 50 x18 mm

Recharge Port

USB Type C / Read Station



   

   

H8 Real time temperature humidity data logger

The H8 series temperature and humidity data logger features wireless real-time transmission, supporting remote online data monitoring and dynamic visual viewing; fully wireless remote operation greatly reduces the workload of manual deployment and reading, significantly improving work quality and efficiency, making it especially suitable for large pharmaceutical warehouses and complex environmental validations.

温湿度数据记录仪 H8.png

FEATURES

  • 5 km ultra-powerful penetration wireless real-time signal: Equipped with long-distance wireless transmission technology, it offers ultra-strong penetration, allowing stable transmission up to 5km. Even in complex environments, it maintains real-time connectivity, making data transmission more reliable.

  • Dual-band high-speed transmission: Utilizing advanced dual-band wireless technology, it provides wider band width and lower latency. Large-volume data can be quickly synchronized and uploaded, ensuring stable, uninterrupted transmission to meet the needs of high-speed, real-time data collection.

  • Compact and portable: Leading electronic technology and structural design make the device compact and small, allowing the logger to flexibly adapt to multiple installation scenarios. It efficiently and conveniently supports spatial deployment and vertical hanging.

SPECIFICATION

Model #

H8-T1H1

Sensor Channel

1 x Inner PT100, 1x Inner RH%, 1 x External sensor

Measurement range

-40℃ to 80℃, 0%...100%RH

Accuracy

±0.2℃, ±2%RH (at 25℃, 20...90%RH)

Storage capacity

50,000 data / channel

Battery

Rechargeable Lithium Battery, 1200mAh

Working Environment

-40℃ to 80℃, 0...100%RH (no condensation)

Dimension (L x W x H)

100 x 50 x 18 mm

Wireless Distance

5 km

Recharge Port

USB Type C / Read Station




T90 Ultra-Low Temperature Freezer Data Logger

A professional-grade ultra-low temperature data logger, specifically designed for ultra-low temperature freezers, can accurately measure in extreme temperatures of -90℃, and it is one of the few temperature data loggers on the market dedicated to ultra-low temperature freezers.

数据记录仪 T90.png

FEATURES

  • -90℃ Durable Operation: Using advanced electronic technology in combination with high-precision electronic components and a full aluminum alloy metal casing, the T90 freezer data logger can still perform accurate and stable measurements in extreme ultra-low temperature environments of -90℃.

  • Battery Replacement Every 2 Years: Equipped with a high-performance, high-capacity built-in battery. Even when operating long-term in ultra-low temperature environments, the battery life can reach 2 years/ 3million records.

  • Compact and Portable: Leading electronic technology and structural design make its form compact and small, allowing the logger to flexibly adapt to various installation and usage scenarios, enabling efficient and convenient spatial deployment.

SPECIFICATION

Model #

T90-T1

Sensor Channel

1 x Inner PT100

Measurement range

-90℃ to 90℃

Accuracy

±0.2℃

Storage capacity

65,000 data / channel

Battery

7.2V/1.8Ah

Working Environment

-90℃ to 90℃

Dimension (L x W x H)

72 x 41 x 18 mm

Material

Aluminum Alloy

Battery Life

2 years / 3 million data









Read Station

Read Station RS8-H6

Wireless Real-Time Read Station WS-2FA (for H8)

Read Station RS8-T90




External Temperature sensor


Digital Wet Resistance Temperature Sensor U-WRS

数字湿热热电阻温度传感器 U-WRS.png

Model #

U-WRS

Accuracy

±0.1℃

Measurement range

-200℃ to 200℃

Head Pacakge

TTP full Teflon protection

Wire Material

Teflon

Working Environment

-40℃ to 80℃, 0...90%RH

Connector size

38 x 20 x 9 mm

Sensor head size

Φ4 x 40 mm

Cable length

2 m, Customize 1~5 m

External Cable

No need




Digital Dry Resistance Temperature Sensor U-DRS  

数字湿热热电阻温度传感器 U-WRS.png

Model #

U-DRS

Accuracy

±0.1℃

Measurement range

0℃ to 400℃

Head Pacakge

316L stainless steel

Wire Material

Polyimide, 304 stainless steel mesh protection

Working Environment

-40℃ to 80℃, 0...90%RH

Connector size

38 x 20 x 9 mm

Sensor head size

Φ3.5 x 35 mm

Cable length

2 m, Customize 1~5 m

External Cable

No need



Digital Temperature & Humidity Sensor

数字湿热热电阻温度传感器 U-WRS.png

Model #

U-WRS

Temperature accuracy

±0.2℃

Temperature range

-40℃ to 80℃

Humidity accuracy

± 2%RH (25℃, 20%...90%RH)

Humidity range

0...100%RH

Working Environment

-40℃ to 80℃, 0...90%RH

Connector size

38 x 20 x 9 mm

Sensor head size

Φ3.5 x 35 mm

Working condition

-40℃ to 80℃, 0...100%RH

External Cable

Needed




Digital CO2 sensor

数字湿热热电阻温度传感器 U-WRS.png


Model #

U-DCS

P7-DCS

Accuracy

± (0.5%FS + 3%RD)

± (0.5%FS + 3%RD)

Measurement range

0...25% CO2

0...25% CO2

Wire Material

-200℃ to 200℃

Teflon

Working Environment

-20℃ to 85℃, 0...100%RH

(no condensation)

-20℃ to 85℃, 0...100%RH

(no condensation)

Connector size

35 x 18 x 9.5 mm

Φ15 x 98 mm

External Cable

Needed

Needed





     

         




Software

Power 3000 Thermal Validation System Software

Wireless Thermal Validation Data.png

 

 

   



 

 

What kind of frequecy are used in this wireless logger?

We use 2.4 GHz and FM433.



Software operating video: