BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • 1/5
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)
  • BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)

BL790 Low Humidity Calibration System (-100℃ to 20℃ dp)

share
copy Link
Facebook
X
LinkedIn
Pinterest
Accuracy ±0.10℃ DP
Range (-100 to +20) ℃ dp
DescriptionFAQ?

Chilled mirror dew point meter is a precise technique for determining the water vapor content is gases by directly measuring dew point or frost temperatures. Using this technique a metal mirror is cooled until it reaches a temperature at which a thin layer of condensation begins to form on it. The dew layer is detected optically, and the mirror is held at that temperature. The mirror temperature, measures with a PRT, is an accurate indicator of the dew or frost point.


The BL790 series solution provides ultra- dry machines capable of generating gas with a dew point below -90°C to supply dry gas, enabling arbitrary adjustment of dew points within the range of -90°C to 20°C, and fully automatic rapid control can be achieved. The complete system consists of BL789 chilled mirror hygrometer, BL793 dew point generator, BL792 dry gas generator, silent oil-free air compressor, cabinet, pipes and manifold.  


FEATURES

  • Modular design, easy to operate

  • Quick response time and fast generate rate

  • High gas generation production

  • Excellent stability


APPLICATION

  • Humidity standards in calibration labs

  • Humidity measurement in industries.



Model BL789 Chilled Mirror Hygrometer

  • BL789-60: (-60 to +20) ℃, ±0.1℃ dp

  • BL789-80: (-80 to +20) ℃, ±0.1℃ dp

  • BL789-90: (-90 to +20) ℃, ±0.1℃ dp



Model BL792 Dry Gas Generator

  • Dry gas minimum dew point: -95℃ dp

  • Inlet gas pressure: ≥0.8MPa

  • Outlet gas pressure: 0.3MPa (Adjustable)

  • Operating temperature: 0℃ to +50℃

  • Storage temperature: -40℃ to +50℃

  • Power supply:100-240VAC

  • Power consume: 40W

  • Dimension: W485mm x D500mm x H266mm

  • Weight: 22kg

  • Principle: Pressure swing adsorption for desiccants



Model BL793 Dew Point Generator

  • Working principle: Mass flow control

  • Dew point range: -65℃ to 15℃(ambient minus 5℃)

  • Stability: ≤ ±0.1℃ DP (30 min)

  • Response: ≤ 1min

  • Hysteresis: None

  • Adjustable flow rate: 0-10L/min

  • Outlet ports: 3

  • Dry gas minimum dew point: -95℃ dp

  • Inlet gas pressure: ≥0.8MPa

  • Outlet gas pressure: 0.3MPa (Adjustable)

  • Gas in/out connector: 1/4 inch Swagelok tube

  • Operating temperature: 0℃ to +50℃

  • Storage temperature: -40℃ to +50℃

  • Power supply:100-240VAC

  • Power consume: 40W

  • Dimension: W800mm x D700mm x H1700mm

  • Weight: 120 kg



SCOPE OF DELIVERY

  • BL789 Chilled Mirror Hygrometer

  • BL792 Dry gas generator

  • BL793 Dew point generator

  • Integrated cabinet with pipes

  • 5 ways manifold



OPTIONAL

  • ISO17025 accredited calibration certificate

  • Silent oil-free air compressor



ORDERING MODEL #

  • BL790-60

  • BL790-80

  • BL790-90



Our cooling methods:

1. -60℃ DP: Semiconductor refrigeration

2. -80℃ DP: Compressor refrigeration

3. -90℃ DP: Stirling refrigeration (1~2W@80K, ≈ -193℃)


How to fast generate the dew point and short the stable time?

We have resolved the following three points:

1. Temperature acquisition data isstable

2. Mirror surface temperature control is stable

3. Light intensityattenuation is stable.

The relative algorithms for above three points can form a control technical closed loop.




Q: What is the lowest measurement dew point ?

Baluntech did -105℃ DP in our lab, as below:


Test  -102C DP.jpg