Chilled mirror dew point meter is a precise technique for determining the water vapor content is gases by directly measuring dew point or frost temperatures. Using this technique a metal mirror is cooled until it reaches a temperature at which a thin layer of condensation begins to form on it. The dew layer is detected optically, and the mirror is held at that temperature. The mirror temperature, measures with a PRT, is an accurate indicator of the dew or frost point.
The BL790 series solution provides ultra- dry machines capable of generating gas with a dew point below -90°C to supply dry gas, enabling arbitrary adjustment of dew points within the range of -90°C to 20°C, and fully automatic rapid control can be achieved. The complete system consists of BL789 chilled mirror hygrometer, BL793 dew point generator, BL792 dry gas generator, silent oil-free air compressor, cabinet, pipes and manifold.
FEATURES
Modular design, easy to operate
Quick response time and fast generate rate
High gas generation production
Excellent stability
APPLICATION
Humidity standards in calibration labs
Humidity measurement in industries.
Model BL789 Chilled Mirror Hygrometer
BL789-60: (-60 to +20) ℃, ±0.1℃ dp
BL789-80: (-80 to +20) ℃, ±0.1℃ dp
BL789-90: (-90 to +20) ℃, ±0.1℃ dp
Model BL792 Dry Gas Generator
Dry gas minimum dew point: -95℃ dp
Inlet gas pressure: ≥0.8MPa
Outlet gas pressure: 0.3MPa (Adjustable)
Operating temperature: 0℃ to +50℃
Storage temperature: -40℃ to +50℃
Power supply:100-240VAC
Power consume: 40W
Dimension: W485mm x D500mm x H266mm
Weight: 22kg
Principle: Pressure swing adsorption for desiccants
Model BL793 Dew Point Generator
Working principle: Mass flow control
Dew point range: -65℃ to 15℃(ambient minus 5℃)
Stability: ≤ ±0.1℃ DP (30 min)
Response: ≤ 1min
Hysteresis: None
Adjustable flow rate: 0-10L/min
Outlet ports: 3
Dry gas minimum dew point: -95℃ dp
Inlet gas pressure: ≥0.8MPa
Outlet gas pressure: 0.3MPa (Adjustable)
Gas in/out connector: 1/4 inch Swagelok tube
Operating temperature: 0℃ to +50℃
Storage temperature: -40℃ to +50℃
Power supply:100-240VAC
Power consume: 40W
Dimension: W800mm x D700mm x H1700mm
Weight: 120 kg
SCOPE OF DELIVERY
BL789 Chilled Mirror Hygrometer
BL792 Dry gas generator
BL793 Dew point generator
Integrated cabinet with pipes
5 ways manifold
OPTIONAL
ISO17025 accredited calibration certificate
Silent oil-free air compressor
ORDERING MODEL #
BL790-60
BL790-80
BL790-90
Our cooling methods:
1. -60℃ DP: Semiconductor refrigeration
2. -80℃ DP: Compressor refrigeration
3. -90℃ DP: Stirling refrigeration (1~2W@80K, ≈ -193℃)
How to fast generate the dew point and short the stable time?
We have resolved the following three points:
1. Temperature acquisition data isstable
2. Mirror surface temperature control is stable
3. Light intensityattenuation is stable.
The relative algorithms for above three points can form a control technical closed loop.
Q: What is the lowest measurement dew point ?
Baluntech did -105℃ DP in our lab, as below: