BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • 1/10
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)
  • BL765 Relative Humidity Generator  (5~95%RH)

BL765 Relative Humidity Generator (5~95%RH)

share
copy Link
Facebook
X
LinkedIn
Pinterest
Stability ±0.1%RH
Accuracy ±0.5%RH uncertainty (k=2))
Range 5%RH~95%RH, 5℃~50℃
DescriptionFAQ?

 

The BL765 is a bench-top relative humidity generator for calibrating a large workload of probes in the laboratory or on site in the field. The system comprises a humidity and temperature controlled chamber that can house up to six humidity sensors. The BL765 works by time-proportioning the flows of dry and saturated air according to the pre-selected relative humidity value. The chamber temperature is controlled by a four-zone Peltier heat pump arrangement for maximum stability and minimum temperature gradient. The saturator assembly can be filled easily with the distilled water reservoir at the front of the unit and the easily accessible desiccator can be re-charged by heating when required.



FEATURES

  • 5%-95%RH humidity range, temperature range 5℃-50℃

  • Better than ±0.5%RH and 0.1℃ uncertainty for dependable humidity probe calibration

  • Rapid humidity and temperature stabilization time, much faster than traditional two-pressure generator.

  • 2.4L chamber, 1.6L effective work volume

  • Program 6 multi-points calibration

  • Compact size and lightweight

  • Modular design, maintenance free

  • Touch screen operation


APPLICATION

  • Test and calibration laboratory

  • Pharmaceutical and biomedicine

  • Automobile manufacturing industry

  • Food industry

  • Dust free workshop




Youtube video   https://youtu.be/JygbjFxTeL0‍


     

SPECIFICATION

  • Control sensor: HygroClip2-S, PT100

  • Humidity measurement range:   5…95%RH   @23±2℃

  • Temperature measurement range: 5 … 50 ℃ (Environment temperature is not more than 23 ± 1℃ while chamber temperature is set at 5℃ )

  • Humidity stability: < ±0.1%RH

  • Temperature stability: < ±0.02℃

  • Humidity ramp/soak changes:   < 10 minutes (5…95%RH)

  • Temperature changes: < 10 minutes (20 to 50℃), < 20 minutes (20 to 5℃)

  • Typical calibration uncertainty (k=2): ±0.5 %RH @ 20℃,   ±0.10℃ @ 5…95%RH

  • Uniformity: ±0.3%RH @ 23℃,   ±0.10℃ @ 23℃

  • Resolution: ±0.1%RH,   ±0.1℃

  • Ports size on the door: 1xΦ12, 7xΦ15, 2xΦ30, 2xΦ50mm

  • Maximum Calibration probes: 8 pcs

  • Water level observation: Front panel window

  • Request water: 80ml – 120ml distilled water

  • Gas connection: Input and output on rear side

  • Desiccant type: Molecular Sieve (screen shows lack)

  • Chamber volume: 2.4L, effective working volume is 1.6 L (14 cm x Φ12cm )  

  • Communication ports: RS485

  • Power supply: 220VAC 60Hz 3A   (110V is optional)

  • Dimension: 475mm L x 360mm W x 240mm D

  • Weight: 15 kg

  • Operation environment: 10°C to 35°C, < 80%RH


 

SCOPE OF DELIVERY

  • BL765 Humidity generator

  • Square door with 8 ports (1xΦ12, 7xΦ15, 2xΦ30, 2xΦ50mm)

  • Desiccant cartridge

  • Fill syringe

  • Power cord

  • User manual

  • Metal Carrying case with wheels and handle


OPTIONAL ACCESSORIES AND SERVICES

  • ISO17025 accredited calibration certificate (CAL-765)

  • Desiccant cartridge with desiccant material (765-DC)  

  • Transparent window for transmitter w/o probe (765-TW)  

  • Door with custom ports from Φ6mm to Φ50mm (765-CP)  


ORDERING MODEL NUMBER

  • BL765-220V

  • BL765-110V



Direct calibrate the UUTs

Examples:

Test Rotronic UUT @25C 20%RH.jpg              

Test Rotronic UUT @45C 80%RH.jpg            

 


Test three UUTs @25C 90%RH.jpg        

Test Rotronic UUT @23C 98%RH.jpg




Work with ±0.20% ℃ DP Chilled Mirror Hygrometer

Examples:

BL765+BL784.jpg

 

Work with ±0.15% ℃ DP Chilled Mirror Hygrometer

Examples:

BL765+BL783.jpg



Test Rotronic UUT @23C 98%.jpg


Work with ±0.10% ℃ DP Chilled Mirror Hygrometer

Examples:

BL756+373  @20C,10%RH.jpg

 

BL756+373  @20C,50%RH.jpg

 

BL756+373 @20C,90%RH.jpg  


BL756+373  @20C,90%RH.jpg




BL756+373  @8C,80%RH.jpg


Customer reference:  

Shanghai Academy of Spaceflight Technology    http://www.sast.spacechina.com/

Shanghai Centre Testing International                     https://www.cti-cert.com/en/

China National Environmental Monitoring Centre   https://www.cnemc.cn/en/

China Meteorological Administration                    https://www.cma.gov.cn/en/

Xichang Satellite Launch Center                     https://english.spacechina.com/





Do you have recomendation for communication software?

We recommend PuTTY.

PuTTY is a communications tool for running interactive command-line sessions on other computers, usually via the SSH protocol.   It can also communicate over a serial port, or speak various legacy Internet protocols such as Telnet.

If necessary, please also download the driver of USB cable.



What is the accuracy of internal control sensor?

The error tolerance of standard control sensor is ±0.8%RH.

Also, the more accurated ±0.6%RH sensor is available, extra cost will be charged.


What is reference standard of BL765?

The BL765 humidity generator can generate a uniform and stable temperature and humidity environment in its chamber. In general, the BL765 can refer the following methods as humidity reference standard:

  • Internal control humidity sensor

  • External high precision humidity probe

  • External chilled mirror hygrometer

  • External standard platinum resistance thermometer (SPRT)

Each methods has its pros and cons, user could select the most reliable reference standard as per the actual measurement requirements.   

N.B:   It is very important to compare the temperature of reference standard, BL765 humidity generator itself, and the unit under test (UUT). To get a very accurate humidity test value, the temperature uncertainty should be optimized firstly. Humidity uniformity is based on temperature uniformity because water molecules in air (water vapor) evenly disperse in a closed system unless temperature is not uniform. Also, since relative humidity (RH) is the percent of water vapor saturation at a particular temperature, it varies with air temperature.


How to measure the 5%RH precisely?

The 5%RH is not easy to get a precised measurement results. It is recommended to use an external air pump to assist the humidity control. And, it will be better to input the whole UUT sensor inside of test chamber.